Unit Heart

SKU:U029

Description

Unit Heart is a blood oxygen and heart rate sensor. It integrates MAX30100, providing a complete pulse oximeter and heart rate sensor system solution. This is a non-invasive blood oxygen and heart rate sensor, integrating two infrared LEDs and a photodetector. Its detection principle is to illuminate with infrared LEDs and detect the ratio of oxygenated to deoxygenated red blood cells to determine blood oxygen levels.

Testing method: After the program runs, place your finger on the detection area.

Heart Unit communicates with M5Core via the I2C protocol, I2C address: 0x57

Features

  • Programmable sampling rate and LED current to save power
  • Ultra-low shutdown current (0.7µA, typical)
  • High measurement performance
  • High sampling rate
  • Built-in temperature sensor calibration
  • Fast data output
  • Blood oxygen concentration detection, heart rate detection
  • Software development platform: Arduino
  • 2 x LEGO compatible holes

Includes

  • 1 x Unit Heart
  • 1 x HY2.0-4P Grove connection cable (20cm)

Specifications

Specification Parameter
Communication Protocol I2C:0x57
Net Weight 5g
Gross Weight 18g
Product Dimensions 32 x 24 x 8mm
Package Dimensions 136 x 92 x 13mm

Schematics

PinMap

Unit Heart

HY2.0-4P Black Red Yellow White
PORT.A GND 5V SDA SCL

Model Size

Datasheets

Softwares

Arduino

UiFlow1

Unit Heart UiFlow1 Docs |How to use Unit Heart in the UiFlow1 graphical programming platform and related API description|

UiFlow2

Unit Heart UiFlow2 Docs |How to use Unit Heart in the UiFlow2 graphical programming platform and related API description|

EasyLoader

Easyloader Download Link Note
Unit Heart Test Easyloader download /

Video

  • Screen displays blood oxygen and heart rate sensor detection values.

FAQ

  • Q: What is the accuracy and resolution of the Heart rate unit?
  • A: Since it is not calibrated and officially verified, the data can only be used as a reference. However, if the numbers suddenly drop, you should pay special attention to whether there is any abnormality in your body. In actual tests, holding your breath for a period of time and then measuring will show lower blood oxygen levels. Measurements on the right finger will also be slightly lower, possibly related to the distance from the heart.