pdf-icon

UIFlow Guide

UIFlow 1.0 Blockly

Event

Unit

UIFlow 1.0 Project

Module COMX LoRaWAN 915

Example

Use the LoRaWAN 915 module to connect to the network via OTAA mode, configure the frequency band and data rate parameters, and periodically send payload data and receive downlink data.
from m5stack import *
from m5ui import *
from uiflow import *
from comx.LoRaWAN import LoRaWAN_915
import time

screen = M5Screen()
screen.clean_screen()
screen.set_screen_bg_color(0xFFFFFF)

flag = None

lora915 = LoRaWAN_915(tx=17, rx=16)
lora915.set_join_mode(0)
lora915.config_OTAA('', '', '')
lora915.set_frequency_band_mask('0002')
lora915.set_rx_window_param(0, 0, 923300000)
lora915.set_class_mode(2)
lora915.set_uplink_downlink_mode(2)
lora915.join(1, 1, 8, 8)
flag = False
while True:
  if not flag and lora915.check_join_status():
    flag = True
    print('Joined')
  if flag:
    lora915.send_data('M5STACK', 1, 5)
    print(lora915.check_downlink_data())
  wait(10)
  wait_ms(2)

API

lora915.check_downlink_data()
  • Check and receive downlink data. This block is used to check whether the LoRaWAN network has sent data to the device and to receive that data.
lora915.check_join_status()
  • Check the device's status of joining the LoRaWAN network. This block is used to confirm whether the device has successfully joined the LoRaWAN network.
lora915.check_uplink_status()
  • Check the status of uplink data. This block is used to confirm whether the device's uplink data has been successfully transmitted to the LoRaWAN network.
lora915.set_frequency_band_mask('0001')
lora915.set_rx_window_param(0, 0, 923300000)
lora915.set_class_mode(0)
lora915.set_uplink_downlink_mode(1)
  • Configure LoRaWAN communication parameters. This block includes the following settings:
    • frequency band mask: Sets the mask range for the frequency band, in this example from 915.2 MHz to 916.6 MHz.
    • RX window param: Configures the receive window parameters.
    • RX1 offset: Sets the frequency offset for the first receive window.
    • RX2 datarate: Sets the data rate for the second receive window (in this example SF12 BW125).
    • RX2 freq: Sets the frequency for the second receive window (in this example 923300000 Hz).
    • class mode: Sets the device's class mode (in this example, class A).
    • uplink downlink: Sets the frequency mode for uplink and downlink data (in this example, same frequency mode).
lora915.config_OTAA('', '', '')
  • Configure the LoRaWAN OTAA (Over The Air Activation) mode.
    • device eui: The device's EUI (unique identifier) used to uniquely identify the device in the LoRaWAN network.
    • app key: The application key used to secure communication between the device and the network.
    • app eui: The application's EUI, used to identify the application with a unique identifier.
lora915.get_ABP_config()
  • Get the configuration parameters for ABP (Activation By Personalization) mode. In ABP mode, the device directly joins the network using pre-configured keys and parameters without needing the OTAA process.
lora915.get_OTAA_config()
  • Get the configuration parameters for OTAA mode. This block is used to read the current device's configuration in OTAA mode.
LoRaWAN_915(tx=0, rx=0)
  • Initialize the LoRaWAN 915 MHz band with transmit (TX) and receive (RX) pins. These pins are used for communication with the LoRaWAN module.
lora915.join(1, 1, 8, 1)
  • Start the process of joining the LoRaWAN network.
    • open: Sets whether to automatically rejoin the network. When "auto join" is selected, the device will automatically attempt to rejoin if the connection is lost.
    • period (seconds): Sets the interval time (in seconds) between each attempt to join the network.
    • maximum number of attempts: Sets the maximum number of attempts. If the device fails to join the network after this number of tries, it will stop attempting.
lora915.join(0)
  • Stop the device's attempt to join the LoRaWAN network. This block is used when the network joining process is no longer needed.
lora915.receive_data()
  • Receive downlink data from the buffer. The LoRaWAN network can send data to the device via the downlink, and this block is used to read that data.
lora915.send_data('')
  • Send a data payload to the LoRaWAN network.
    • unconfirm/confirm: Choose whether the sent packet requires confirmation (confirm) or not (unconfirm). Choosing confirmation increases communication reliability but may also increase latency.
lora915.set_join_mode(0)
  • Set the device's join mode to OTAA (Over The Air Activation), which is the recommended secure method for joining the LoRaWAN network.
lora915.set_uplink_app_port(1)
  • Set the application port for LoRaWAN uplink data. This port is used to identify

which application the data packet is sent to on the network server.

  • Range: The port number ranges from 1 to 233. Each port number corresponds to a specific application or service, and choosing the correct port ensures that the data is processed correctly.