pdf-icon

UIFlow Guide

UIFlow 1.0 Blockly

Event

Unit

UIFlow 1.0 Project

Unit Kmeter Iso

Example

from m5stack import *
from m5ui import *
from uiflow import *
import unit

setScreenColor(0x222222)
KMeterISO_0 = unit.get(unit.KMETER_ISO, unit.PORTA)

KMeterISO_0.init_i2c_address(0x66)
print((str('Version:') + str((KMeterISO_0.get_firmware_version()))))
print((str('I2C address:') + str((KMeterISO_0.rw_i2c_address()))))
while True:
  print((str('thermocouple::') + str((KMeterISO_0.get_kmeter_thermo(1)))))
  print((str('internal:') + str((KMeterISO_0.get_kmeter_internal(1)))))
  wait_ms(2)

API

KMeterISO_0.init_i2c_address(0x66)
  • Initializes the i2c address of the device. The default is 0x66
print(KMeterISO_0.get_firmware_version())
  • Obtain the firmware version of the device
print(KMeterISO_0.rw_i2c_address())
  • Obtain the i2c address of the device
print(KMeterISO_0.get_kmeter_internal(1))
  • Get the internal temperature of the chip (Celsius or Fahrenheit)
    • CELSIUS
    • FAHRENHEIT
print(KMeterISO_0.get_isready())
  • Set the device to start measuring temperature
print(KMeterISO_0.get_kmeter_internal_string(1))
  • Output the chip temperature as a string
    • CELSIUS
    • FAHRENHEIT
print(KMeterISO_0.get_kmeter_thermo_string(1))
  • Output the temperature of the thermocouple as a string
    • CELSIUS
    • FAHRENHEIT
print(KMeterISO_0.get_kmeter_thermo(1))
  • Get thermocouple temperature
    • CELSIUS
    • FAHRENHEIT
KMeterISO_0.rw_i2c_address(0x66)
  • Set the i2c address of the device